| Sign In | Join Free | My chinacomputerparts.com | 
 | 
Brand Name : Lonroy
Model Number : LRTD
Certification : Includes Calibration Certification
Place of Origin : China
MOQ : 1
Price : Negotaible
Payment Terms : L/C,D/A,D/P,T/T,Western Union
Supply Ability : 200
Delivery Time : 5-8 work days
Packaging Details : Wooden package
Frequency Coverage Ratio : 16000:1
Frequency Range : 100 kHz - 160 MHz
Measurement Diameter : Ø 38 mm
Thickness Range : < 15 mm
Warranty : 1 Year
ASTM D 150 Permittivity Tester Ceramics Composites Dielectric Constant Meter
1.Description:
The LRTD high-frequency insulation material dielectric constant and dielectric loss testing system consists of a testing device (clamping fixture), a high-frequency Q-meter, data acquisition and tanδ automatic measurement control (software module incorporated into LRTD), and an inductor. It is designed and manufactured in accordance with the national standards GB/T 5594.4-2015 "Test methods for performance of structural ceramic materials of electronic components - Part 4: Test methods for dielectric constant and dielectric loss tangent value", GB/T 1693-2007 "Determination of dielectric constant and dielectric loss tangent value of vulcanized rubber", GB/T 1409-2006, GB/T 1693-2007, American standard ASTM D150, and International Electrotechnical Commission IEC 60250. The system provides the best solution for automatic measurement of the high-frequency dielectric loss tangent value (tanδ) and dielectric constant (ε) of insulation materials. The testing device in this instrument is composed of a flat capacitor, which is generally used to clamp the tested sample and is equipped with a Q-meter as an indicating instrument. The dielectric loss tangent value of the insulation material is calculated by the change in Q value and the scale reading of thickness when the tested sample is placed in the flat capacitor and when it is not placed. Using the LRTD digital Q-meter enables automatic calculation of dielectric constant (ε) and dielectric loss (tanδ).
2.Configuration:
Includes 1 LRTD-C test host, 1 sample fixture, and 1 set of inductors (10 pieces). Optional liquid cup is available for testing liquid materials.
3.Technical Parameter
System composition of the LRTD dielectric constant/loss test system:
Main unit: High-frequency Q-meter
| Feature Category | Parameter | Specification / Value | Notes | 
| Source | Signal Source Type | DDS Digitally Synthesized Signal | |
| Frequency Range | 100 kHz - 160 MHz | ||
| Frequency Coverage Ratio | 16000:1 | ||
| Frequency Accuracy | 3 × 10⁻⁵ ±1 count (6 significant digits) | ||
| Sampling | Sampling Accuracy | 12-BIT | Ensures Q stability & low Df material testing stability | 
| Q Measurement | Q Measurement Range | 1 - 1000 | Auto/Manual Range | 
| Q Resolution | 0.1 (4 significant digits) | ||
| Q Measurement Error | < 5% | ||
| Inductance (L) Measurement | L Measurement Range | 1 nH - 140 mH | Resolution 0.1 nH (4 significant digits) | 
| L Measurement Error | < 3% | ||
| Tuning Capacitor | Main Capacitance Range | 17 pF - 240 pF | High-precision silver-plated monolithic structure | 
| Capacitance Auto-Search | Yes | With stepper motor | |
| Direct C Measurement Range | 1 pF ~ 25 nF | ||
| Tuning Capacitor Error | ±1 pF or < 1% | ||
| Tuning Capacitor Resolution | 0.1 pF | ||
| Resonance | Resonance Point Search | Auto Scan | |
| Q Features | Q Pass/Fail Preset Range | 5 - 1000 | Audible/Visual Indication | 
| Q Range Switching | Auto/Manual | ||
| Display (LCD) | Displayed Parameters | F, L, C, Q, Lt, Ct, tn, Σr | F=Freq, L=Ind, C=Cap, Q=Quality Factor, Lt/Ct=tuned, tn=?, Σr=Series R? | 
| Unique Features | Auto Residual Inductance Deduction | Yes | Residual inductance & lead inductance (Unique) | 
| Large Capacitance Direct Display | Yes | Up to 25 nF (Unique) | |
| Material Testing | Dissipation Factor (Df) Accuracy | 0.01% (1/10,000) | |
| Permittivity (εᵣ) Accuracy | 0.1% (1/1,000) | ||
| Material Thickness Range | 0.1 mm - 10 mm | ||
| Permittivity Display | Directly on LCD | ||
| Dissipation Factor Display | Directly on LCD | ||
| Permittivity Test Frequency Range | 100 kHz - 100 MHz | 
Dielectric constant εr and dielectric loss factor tanδ testing device:
| Feature | Specification | Notes | |
| Solid Samples | Measurement Diameter | Ø 38 mm | |
| Thickness Range | Adjustable, < 15 mm | Typical range | |
| Electrode Plates | Customizable | (Optional customization) | 
Inductors
| No. | Inductance (L) | Accuracy | Q Factor ≥ | Approx. Distributed Capacitance (C<sub>d</sub>) | Resonance Frequency Range (MHz) | Recommended Frequency for Permittivity Test | 
| 1 | 0.1 μH | ±0.05 μH | 200 | 5 pF | 31 - 103 | 50 MHz | 
| 2 | 0.5 μH | ±0.05 μH | 200 | 5 pF | 14.8 - 46.6 | 15 MHz | 
| 3 | 2.5 μH | ±5% | 200 | 5 pF | 6.8 - 21.4 | 10 MHz | 
| 4 | 10 μH | ±5% | 200 | 6 pF | 3.4 - 10.55 | 5 MHz | 
| 5 | 50 μH | ±5% | 200 | 6 pF | 1.5 - 4.55 | 1.5 MHz | 
| 6 | 100 μH | ±5% | 200 | 6 pF | 1.06 - 3.20 | 1 MHz | 
| 7 | 1 mH | ±5% | 150 | 8 pF | 0.34 - 1.02 | 0.5 MHz | 
| 8 | 5 mH | ±5% | 130 | 8 pF | 0.148 - 0.39 | 0.25 MHz | 
| 9 | 10 mH | ±5% | 90 | 8 pF | 0.107 - 0.32 | 0.1 MHz | 
| 10 | 14 nH | ±5% | 100 | 5 pF | ~100 MHz | 100 MHz | 
|   | 
| ASTM D 150 Permittivity Tester Ceramics Composites Dielectric Constant Meter Images | 
 Ceramic Tile Glaze Cracking Tester For Ceramic Tile Anti Cracking Test ISO10545
                                                                                    
                        
                        
                        
                                                            Ceramic Tile Glaze Cracking Tester For Ceramic Tile Anti Cracking Test ISO10545
                                                    
                        
                     LRH Series ISO 8302 Multifunctional Fast Thermal Conductivity Tester
                                                                                        
                                                        
                        
                        
                        
                                                            LRH Series ISO 8302 Multifunctional Fast Thermal Conductivity Tester
                                                    
                        
                     LRH-300 Thermal Conductivity Tester For Heat Insulation Materials
                                                                                        
                                                        
                        
                        
                        
                                                            LRH-300 Thermal Conductivity Tester For Heat Insulation Materials
                                                    
                        
                     LRH-400 Thermal Conductivity Tester Heat Shield Plate Method
                                                                                    
                        
                        
                        
                                                            LRH-400 Thermal Conductivity Tester Heat Shield Plate Method
                                                    
                        
                     LRH-II-300 Automatic Thermal Conductivity Tester Double Heat Insulation Plate
                                                                                        
                                                        
                        
                        
                        
                                                            LRH-II-300 Automatic Thermal Conductivity Tester Double Heat Insulation Plate
                                                    
                        
                     0 - 1000N Thermal Conductivity Tester Instrument Heat Protection Plate Method
                                                                                        
                                                        
                        
                        
                        
                                                            0 - 1000N Thermal Conductivity Tester Instrument Heat Protection Plate Method
                                                    
                        
                     ASTM C 518 Protective Plate Heat Flux Meter Method Thermal Conductivity Tester
                                                                                        
                                                        
                        
                        
                        
                                                            ASTM C 518 Protective Plate Heat Flux Meter Method Thermal Conductivity Tester
                                                    
                        
                     LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter
                                                                                        
                                                        
                        
                        
                        
                                                            LRS Series 1000ºC Thermal Conductivity Tester Guarded Plate Heat Flow Meter
                                                    
                        
                     LRH-GW Thermal Conductivity Tester High Temperature Heat Shield Method Thermal
                                                                                    
                        
                        
                        
                                                            LRH-GW Thermal Conductivity Tester High Temperature Heat Shield Method Thermal
                                                    
                        
                     Thermal Effusivity Analyzer Thermal Property Measurement Machine
                                                                                        
                                                        
                        
                        
                        
                                                            Thermal Effusivity Analyzer Thermal Property Measurement Machine